Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe
operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. U.L. r ecognized
under file number MH 20567.
Sealed Lead-Acid Battery
L: 12.05in (306.1 mm)
W: 6.61in (167.9 mm)
H: 8.27in (210.1 mm)
TH: 9.13in (231.9 mm)
Tolerances are +/- 0.04 in. (+/- 1mm)
and +/- 0.08 in. (+/- 2mm) for height
dimensions. All data subject to
change without notice.
Nominal Voltage
Nominal Capacity
20-hr. (4.50A)
10-hr. (8.37A)
5-hr. (15.30A)
1-hr. (54.00A)
Approximate Weight
Internal Resistance (approx.)
Shelf Life (% of normal capacity at 77º F (25º C))
3 Months 6 Months 12 Months
Temperature Dependancy of Capacity
104º F 77º F
12 volts
90 Ah
27 A or smaller
14.5-14.9 V
77º F (25º C)
(20 hour rate)
83.7 Ah
76.5 Ah
54 Ah
59.5 lbs (27 kgs)
7 mΩ
91% 82% 64%
102% 100% 85%
32º F 5º F
Charge Method
65%
(Constant Voltage)
Cycle Use
Float Use
Initial Current
Control Voltage
13.6-13.8 V
Control Voltage
(Repeating Use)
Specification
Physical Dimensions: in (mm)
Terminals
F1206-1
UPG No. 45826
Maintenance-Free
UB12900
306 (12.05)
210 (8.27)
168 (6.61)
5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR F.V/Time
309.3 225.7 158.8 96.1 50.2 29.3 21.5 16.7 13.8 9.7 8.8 4.7 9.60V
272.5 205.7 142.1 91.1 47.2 27.9 20.9 16.3 13.5 9.5 8.5 4.6 10.20V
262.5 195.6 133.8 88.6 46.0 27.3 20.4 16.1 13.4 9.4 8.4 4.6 10.50V
252.5 185.6 125.4 86.1 44.3 26.6 19.9 15.8 13.0 9.2 8.4 4.5 10.80V
242.4 175.6 117.0 83.6 42.6 25.9 19.2 15.3 12.7 8.9 7.9 4.3 11.10V
Constant Current Discharge Characteristics Unit:A (25°C, 77°F)
5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR F.V/Time
3284.6 2480.4 1687.0 1020.8 581.0 338.6 249.1 194.0 159.7 112.9 102.0 54.9 9.60V
3025.5 2283.1 1577.5 1011.6 545.9 323.5 242.4 188.9 125.5 110.4 99.5 53.5 10.20V
2977.0 2218.7 1516.5 1004.9 528.4 316.0 236.6 185.6 154.7 109.5 97.8 52.8 10.50V
2938.5 2160.2 1459.7 1002.4 514.1 309.3 231.6 182.2 152.2 107.0 97.0 52.6 10.80V
2885.0 2089.2 1392.8 994.8 507.5 308.5 229.1 181.4 151.3 106.2 94.5 51.0 11.10V
Constant Power Discharge Characteristics Unit:W (25°C, 77°F)
eLine Technology
eLineTechnology.com
1
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - UB12900

Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safeoperation in any position. Appro

Seite 2

Charge Voltage(V/Cell) Application Temperature Set Point Allowable Range Max.Charge Current Cycle Use 25 (77 ) 2.45 2.40~2.50 Standby 25 (77 ) 2.325

Kommentare zu diesen Handbüchern

Keine Kommentare